BXMYL - 19152 ULTRA ETCH MAKE UP SOLUTION

  • MSDS: BXMYL
  • Manufacturer: MACDERMID INC
  • Product Name: 19152 ULTRA ETCH MAKE UP SOLUTION
  • National Stock Number: 6850-00F041052
Product Identification

Product ID:19152 ULTRA ETCH MAKE UP SOLUTION
MSDS Date:03/22/1991
FSC:6850
NIIN:00F041052
MSDS Number: BXMYL

Responsible Party
MACDERMID INC
245 FREIGHT ST
WATERBURY, CT 06702-5000
US

Emergency Phone: 203-575-5700/313-644-5626

Info Phone: 203-575-5700/203-575-5606

Cage: MACDE

Contractor
MACDERMID INC.(FRMLY ALLIED-KELITE)
WATERBURY, CT 06702 US

Telephone: 203-575-5606/800-424-9300(CHEMTREC)

Cage: 0PX54

Ingredients

LEAD SALT

Fraction By Weight: TRACE


AMMONIUM HYDROXIDE, AQUA AMMONIA

CAS: 1336-21-6

RTECS: BQ9625000

Fraction By Weight: 1-5%

ACGIH TLV: 25 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


AMMONIUM CHLORIDE

CAS: 12125-02-9

RTECS: BP4550000

Fraction By Weight: 15-25%

OSHA PEL 10 MG/CUM

ACGIH TLV: 10 MG/CUM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


COPPER CHLORIDE

CAS: 1344-67-8

RTECS: GL6970000

Fraction By Weight: 15-30%

Hazards

LD50 LC50 Mixture:ORAL LD50(RAT): 1650 MG/KG (SEE SUPP)
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: SEVERE IRRITANT, INTENSIVE
BURNS. SKIN: BURNING SENSATION, IRRITANT & DAMAGE TO TISSUES
W/PROLONGED EXPOSURE. INGESTION: POISON. IRRITANT & BURNING
SENSATION OF LIPS, MOUTH & THROAT. INHALATION: POISON. IRRITATION
OF MUCOUS MEMBRANE OF NOSE, MOUTH & THROAT.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:BURNING, STINGING SENSATION, WATERING OF EYES,
IRRITATION, PAIN IN SWALLOWING, INTENSE THIRST, NASAL DISCHARGE,
SNEEZING, COUGHING/COUGHING FITS

First Aid

First Aid:EYES: WASH UNDER SLOWLY RUNNING WATER FOR 15 MINS. SKIN: WASH
W/WATER FOR 15 MINS. INGESTION: RINSE MOUTH & THROAT LIBERALLY
W/WATER. INHALATION: REMOVE TO COOL UNCONTAMINATED AREA, MONITOR
FOR RESPIR ATORY DISTRESS. IF UNCONSCIOUS, HAVING TROUBLE
BREATHING/CONVULSIVE, DON'T INDUCE VOMITING/GIVE WATER. NEVER GIVE
ANYTHING TO AN UNCONSCIOUS PERSON. OBTAIN MEDICAL ATTENTION IN ALL
CASES.

Fire Fighting

Extinguishing Media:WATERSPRAY, CO2, DRY CHEMICAL, FOAM, HALON, AS
APPROPRIATE FOR SURROUNDING MATERIAL.
Fire Fighting Procedures:NEVER ALLOW RUN-OFF TO ENTER SEWERS/WATERWAYS.
WEAR SELF CONTAINED BREATHING APPARATUS & PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:WHEN HEATED CORROSIVE FUMES ARE EMITTED.

Accidental Release

Spill Release Procedures:SOAK UP INTO INERT ABSORBENT MATERIAL. DON'T
USE SAWDUST. COLLECT FOR DISPOSAL IN PLASTIC RECOVERY DRUM. FLUSH
RESIDUE W/PLENTY OF WATER TO CHEMICAL DRAIN. NEVER ALLOW TO ENTER
SEWERS/WATERWAYS.

Handling

Handling and Storage Precautions:MATERIAL SHOULD BE STORED IN THE
PROPERLY SEALED ORIGINAL CONTAINER. ACID BEARING MATERIAL SHOULD BE
STORED SEPARATE FROM ALKALINE MATERIALS.
Other Precautions:DON'T STORE CORROSIVE MATERIALS ABOVE, BELOW/ADJACENT
TO FLAMMABLE SOLIDS, OXIDIZING MATERIALS/CYANIDE BEARING MATERIALS
(POISONS). MUST BE USED W/ADEQUATE VENTILATION.

Exposure Controls

Respiratory Protection:IF PEL/TLV IS EXCEEDED, IT IS RECOMMENDED THAT A
NIOSH APPROVED RESPIRATOR BE USED. LARGE: FOR ENTRY INTO LARGE
TANKS, VESSELS/ENCLOSED SMALL SPACES W/INADEQUATE VENTILATION, A
PRESSURE DEMAND, SCBA I S RECOMMENDED.
Ventilation:LOCAL EXHAUST WHERE VAPORS, DUSTS, MISTS/AEROSOLS MAY BE
RELEASED.
Protective Gloves:RECOMMENDED
Eye Protection:SPLASH PROOF GOGGLES/FACE SHIELD
Other Protective Equipment:CHEMICAL APRONS, BOOTS, EYE WASH FOUNTAIN,
SAFETY SHOWER
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
INFORMATION FOR ORAL LD50 IS FOR: AMMONIUM CHLORIDE. PH: 8.2-8.8.

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:32F
Spec Gravity:1.2
pH:(SUPP)
Solubility in Water:COMPLETE
Appearance and Odor:BLUE LIQUID W/AMMONICAL ODOR

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS, COPPER, TIN, ZINC, ALUMINUM
Hazardous Decomposition Products:OXIDES OF NITROGEN & AMMONIA VAPORS

Disposal

Waste Disposal Methods:DISPOSE OF BY AN APPROVED METHOD AT AN APPROVED
SECURE FACILITY IN ACCORDANCE W/LOCAL, STATE & FEDERAL REGULATIONS.
CORROSIVE MATERIAL NA1719.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.